| Sl. |
Cable nomenclature |
Inner conductor
mm |
Dia over dielectric
mm |
Shielding braid
mm |
Overall dia of cable
mm |
Attenuation
dB/mtr at 100 MHz |
Maximum operating voltage
Volts (rms) |
| RG Series cables |
| 1. |
RG-174 |
7/0.16 Plain annealed copper |
1.52 |
1 braid, tinned annealed copper wire |
2.54 |
1.33 At 200 MHz |
1500 |
| 2. |
RG-122/U |
27/0.127 Tinned copper conductor |
2.44 |
1 braid, tinned annealed copper wire |
2.54 |
1.20 At 200 MHz |
1900 |
| 3. |
RG-5 B/U |
1.29 Silver coated solid copper |
4.60 |
2 braids, silver coated copper wire |
8.43 |
0.08 |
3000 |
| 4. |
RG-8 A/U (Also named RG-213/U, equivalent to UR-67, URM-67) |
7/0.75 Plain annealed copper |
7.25 |
1 braid, plain annealed copper wire |
10.30 |
0.066 |
4000 |
| 5. |
RG-10 A/U |
7/0.72 Plain annealed copper |
7.25 |
1 braid, plain annealed copper wire |
12.10 |
0.12 at 200 MHz |
5000 |
| 6. |
RG-14 A/U |
2.60 Plain copper conductor, solid |
9.40 |
2 braids, plain annealed copper wire |
13.85 |
0.046 |
5500 |
| 7. |
RG-17 A/U |
4.78 Plain copper conductor, solid |
17.27 |
1 braid, plain annealed copper wire |
22.10 |
0.026 |
11000 |
| 8. |
RG-58 |
19/0.18 Tinned copper conductor |
2.95 |
1 braid, tinned annealed copper wire |
4.95 |
0.77 At 200 MHz |
1900 |
| 9. |
RG-174 |
7/0.16 Plain annealed copper |
1.52 |
1 braid, tinned annealed copper wire |
2.54 |
1.33 |
1500 |
UR Series cables
BS-2316 (Defstan 61-12(Part-9)) |
| 1. |
UR-43 |
0.81 Plain annealed copper, solid |
2.60 |
1 braid, plain annealed copper wire |
4.95 |
0.21 |
2750 |
| 2. |
UR-57 |
1.12 Plain annealed copper, solid |
8.13 |
1 braid, plain annealed copper wire |
10.30 |
0.10 |
5000 |
| 3. |
UR-74 |
4.78 Plain annealed copper, solid |
17.27 |
1 braid, plain annealed copper wire |
22.10 |
0.054 |
15000 |
| 4. |
UR-76 |
19/0.17 Annealed tinned copper |
2.95 |
1 braid, plain annealed copper wire |
4.96 |
0.30 |
1800 |